Bridging 71
T0008-16F Release 5.2M
Bridge Filtering
Configuring the Protocol Filter Table
Introduction The Protocol Filter Table prevents stations operating with a certain protocol from
operating outside their intended scope. This filtering action is applied to that part of
the frame that defines the protocol carried by the frame.
Note
A Table boot must be performed to implement changes to the Protocol Filter
Table parameters.
Protocol Filter
Table Parameters
Figure 36 shows the Protocol Filter Table parameters.
Figure 36. Configure Protocol Filter Table Menu
Parameters These parameters make up the Protocol Filter Table Record.
Node: Address: Date: Time:
Menu: Configure Bridge Path:
Bridge Parameters
Bridge Link Parameters
MAC Address Filter Table
Protocol Filter Table
Entry Number
Protocol Type
Protocol Value
Incoming Protocol Link Action
Outgoing Protocol Link Action
Entry Number
Range: 1 to 100
Default: 1
Description: Entry number used to reference this table record.